Knowledge of LED spectrometers

Time: 2023-03-21 10:16:19

Click:

Today, let's take you to learn about LED spectrometers. LED spectrometers are machines that classify and screen the wavelength (color), intensity, and current voltage of the light emitted by LEDs.

Today, let me introduce you to LED spectrometers

LED spectrophotometer is a machine that classifies and screens the wavelength (color), intensity, and current voltage of the light emitted by LEDs.

Components

(1) High speed optical spectrometer; (2) Electrical parameter measuring instrument; (3) Mechanical conveying system; The most core and critical part is the high-speed optical spectrometer. Due to the requirement of the LED spectrometer to achieve a sorting speed of over 10000 LEDs per hour, there is a high demand for the detection and data processing speed of the optical spectrometer.

Product types

SMD LED (SMD) splitter; High power LED spectrometer. Double legged single crystal, double legged twin crystal, triple legged twin crystal Φ 3 Φ 5 Φ 8 Φ 10 class round head and bullet head LED chip lights

Spectral materials

0603/0805/1210/5050 is a common splitter model for LED spectrometers.

0603: Converted to metric system, it is 1005, indicating that the length of LED components is 1.00MM and the width is 0.5MM, abbreviated as 1005 in the industry

0805: Converted to metric system, it is 2125, indicating that the length of LED components is 2.00MM and the width is 1.25MM, abbreviated as 2125 in the industry

1210: Converted to metric system, it is 3528, indicating that the length and width of LED components are 3.5MM and 2.8MM, abbreviated as 3528 in the industry

5050: This is the metric nomenclature, indicating that the length and width of LED components are 5.00MM and 5.00MM, commonly referred to as 5050 in the industry


Product features

1. Measurable wavelength λ= 200-1100nm, light intensity Iv=0-100000 mcd CIE visual function detector;

2. Adopting unique white light measurement methods and optical devices, and more advanced white light color separation technology;

3. Can test any package of common cathode or common anode, Wafer, S or Lamp packages of single leg single crystal, double leg twin crystal, or triple leg twin crystal, can test infrared emitting and receiving tubes;

4. The measurement standards can be traced back to CIE127-1997, Instrument Systems, NIST, and Keithley;

5. Optical measurement sensing devices such as integrating spheres, visual function photodetectors, or spectroscopic spectrometers can be selected;

6. Real time CIE coordinate map and landing point display;

7. Resolution of 16 bit constant current and voltage source and digital measurement meter;

8. The Kelvin method is used in the electrical measurement circuit to avoid measurement errors caused by contact resistance and line resistance;

9. A comprehensive report printing and data statistics system;

10. A full range of LED testing system solutions, using PC based devices, providing fast and flexible automatic testing and human-machine interaction interfaces;

11. Users can freely define the voltage and current source values, set the upper and lower limits of the test items, and arrange the output BIN bits of the measured values at will;

12. Quick grading setting function.

13. Can analyze the coordinate positions of blue light wavelength and white light synthesized from yellow fluorescent powder. [2]


Important product parameters

1. Current voltage measurement:

Current source range: 0-350mA

Current source accuracy: ± 0.1%/16 bits ± 6uA

Voltage source range: 0-20V

Voltage source accuracy: ± 0.05%/16 bits ± 0.38mV

4-level programmable measurement gain: 0.1/0.5/1.0/10.0

Voltage measurement range: 0~± 100V/0~± 20V/0~± 10V/0~± 1V

Voltage measurement accuracy: ± 0.1% ± 2mV


2. Voltage current measurement:

Voltage source range: 0-20V

Current source range: 0-350mA

4-level programmable measurement gain: 0.1/0.5/1.0/10.0

Voltage measurement range: 0~± 100V/0~± 20V/0~± 10V/0~± 1V

Current measurement accuracy: ± 0.1% 0.03uA


3. Light intensity measurement:

Range: 0-100000 mcd

Accuracy: ± 5%

Repeatability: ± 0.5%


4. Color measurement:

Spectrometer/detector type:

Ocean Optics USB2000+ /Sony Silicon CCD,2048Pixels

Ocean Optics USB4000 /Toshiba Silicon CCD,3648Pixels

Control Development Inc. PDA-512-ISA/USB

Wavelength range: 350~1050nm/320~1020nm

Spectral exposure time:1ms~65535ms

spectral resolution :1.0nm

Pixel resolution:0.3nm

Chroma coordinate resolution:0.003

What other professional product knowledge do you need to know? Please leave a message and we will organize and offer it to you.


0
图片展示

 Tel:18018712764

 E-mail:huangtz@tec-pho.com

Address:3rd Floor, Building B, No. 84 Xinyu Road, Xinqiao Street, Bao'an District, Shenzhen City, Guangdong Province

About Us


· Company culture

· Honor

Product

 

· Probe station

· Chip testing machine

· Blue film braiding machine

· LED spectrophotometer

· More products

News

 

· Company News

· Industry News

Contact


· Online Message

图片展示

Website registration:粤ICP备12034829号

Copyright© 2024 Tec Semiconductor Equipment (Shenzhen) Co., Ltd

Service Center

Please choose online customer service to communicate

Contacts
热线电话
0755-27908832
手机
18018712764
上班时间
周一到周五
E-mail地址
huangtz@tec-pho.com
Scan a QR Code
Qrcode
扫码关注视频号
Qrcode
扫码关注公众号
Qrcode
扫码加好友
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了